Triple
ITS Roadway Equipment to Connected Vehicle Roadside Equipment: conflict monitor status
Flow Description
A control flow that supports failsafe operation in the event that a conflict is detected that requires the RSE to enter a failsafe operating mode. Analogous to a traffic signal conflict monitor, this flow is issued when differences are detected between information provided to the vehicle for in-vehicle display and information displayed by field devices. It contains the details of differences that were found.
|
|
Solutions
Solution Description
This solution is used within the U.S. It combines standards associated with US: NTCIP Traffic Signal with those for I-F: OMG DDS RPC. The US: NTCIP Traffic Signal standards include upper-layer standards required to implement centre-to-field traffic signal communications. The I-F: OMG DDS RPC standards include lower-layer standards that support secure remote procedure calls between a field device and another field device or a centre over a field communication link
|
|
Triple Solution Gap
|
|
ITS Info
NTCIP 1202
![]() CEN ISO 19091 ![]() |
Click gap icons for more info.
|
||
|
Mgmt
NTCIP 1201
![]() OMG DDS ![]() |
Facility
![]()
OMG DDS
![]() OMG DDS-RPC ![]() OMG DDSI-RTPS ![]() |
Security
OMG DDS-Security
![]() |
|
|
TransNet
|
|||
|
SubNet
|
|||